Lighting for offices

Home > Lighting for offices

More information

Office lighting: the workspace, reception and meeting rooms

People spend long hours in the office, so the lighting has to serve the work first: light that is easy on the eyes, free of glare, and right for the screen, the desk and the conversation. Then it also gives the office its character, at reception, in the meeting rooms and in the management offices.

The workspace

In the workspace, even light and low glare (UGR) matter most. Recessed lights, light profiles and track systems by Flexalighting and DiaNoche give orderly, quiet light, and a track system lets you move and add fixtures when the desks change.

Reception, meeting rooms and management offices

Here the lighting is also part of the design. Pendant lamps over the meeting table, wall lamps and floor lamps give the room its character. Occhio, a German brand from Munich, is built as a modular system of head and body with interchangeable heads, lenses and filters, and Penta is an Italian company that works together with architects.

Colour of light and control

The colour of the light affects how the space feels and how materials and faces look. Dimming and control let you match the light to a meeting, a presentation on screen or the end of the day.

What Barami Lighting brings to the project

  • Lighting design and lighting calculations for the project.
  • BIM, DWG and 3D files on request, and specifications and photometric files (IES/LDT) to download on the product pages.
  • Support for the project on site as well.

For architects, interior designers and lighting consultants, everything is gathered on the page For architects and designers.

Among Barami Lighting’s clients: Y. Rabinowicz Law Offices and BDSK Ben David Shalvi Kop. The full list is on the page Clients.

Office lighting in numbers: what the standard sets

Office lighting has a European standard, EN 12464-1, for the lighting of indoor work places. It does not say which fixture to use; it says what the room has to achieve:

Read the full guide
  • Amount of light: 500 lux on the work surface for computer work, writing and reading, and in meeting rooms as well. Corridors and circulation areas need about 100 lux. These values have to hold over the life of the installation, so the design keeps a small margin.
  • Glare: a UGR of 19 at most at the desks and in meeting rooms. The lower the number, the less the fixtures dazzle.
  • Colour rendering: Ra 80 or more in the work areas. The Occhio fixtures further down go well beyond it: CRI 95 for Mito sospeso and CRI 97 for Sento tavolo.

The colour of the light is left to choice. Most offices use 4000K, neutral white, at the desks and in meeting rooms, and 3000K, warm white, at reception, in the kitchenette and in waiting areas. One room is best kept to one colour; the change from one to the other happens between spaces.

How many fixtures will meet these figures, and where they go, is checked in a lighting calculation: the room’s dimensions, the ceiling height and the fixture’s photometric file (IES/LDT) go into the calculation software, which returns the light levels and UGR values before anything is ordered.

Tips for each area of the office

Desks and open space

Over the desks, broad, calm light works best, from recessed ceiling lights whose light source sits deep inside the fixture, or from LED profiles. Run the rows of fixtures beside the desks and parallel to the direction of view, not straight above the screens: the light reaches the desk, and the fixture does not show up as a bright spot on the screen.

Meeting rooms and video calls

Over the meeting table, a dimmable pendant lamp works well, with soft light on the walls around it. For video calls, watch what is behind the people at the table: a window or a brightly lit wall behind them darkens their faces on camera, so light the wall facing them and keep the light behind them lower. An example from the catalogue: Occhio’s Mito sospeso, a pendant lamp that fades gradually between up-light and down-light (up / down fading), changes colour between 2700K and 4000K and supports DALI-KNX, so it can join a control system that stores scenes such as meeting, presentation and video call, each called up at the touch of a button.

Reception, lobby and management offices

These areas make the office’s first impression, so this is where a designer fixture pays off: a striking pendant over the reception desk, wall lamps in the lobby and the corridor, and in the manager’s office a table lamp beside the general light. With Occhio’s Sento tavolo, up-light and down-light are controlled separately, the base rotates and the arm tilts, so the same lamp lights the desk and adds soft light to the room. Barami Lighting is the exclusive representative in Israel of Occhio, Catellani & Smith, Terzani, Penta and Venicem.

A lighting calculation before the order

Barami Lighting provides lighting design and lighting calculations for the project from the makers’ photometric files, and checks the figures above for each area of the office. One decision is worth making at this stage: which areas will be dimmed, and with which control system, for example DALI, because it sets the wiring the electrician will lay.

Questions and answers: office lighting

How many lux does an office need?

Under EN 12464-1, the European standard for the lighting of work places: 500 lux on the work surface for computer work, writing and reading, and in meeting rooms as well, and about 100 lux in corridors. These values have to hold over time, not only on the day of installation. How many fixtures it takes depends on the room’s dimensions, the ceiling height and the fixture itself, so it is checked in a lighting calculation.

What is UGR and what value does an office need?

UGR (Unified Glare Rating) measures the glare from light fixtures: the lower the number, the less glare. EN 12464-1 requires a UGR of 19 at most at the desks and in meeting rooms. Makers state a value in the specification, but the actual value also depends on the room’s dimensions and on where the fixtures are placed, so it is checked in the calculation. In the fixture itself, glare drops when the light source sits deep inside it, with dedicated optics or an anti-glare louvre.

4000K or 3000K: which colour of light suits an office?

The standard does not set a colour. Most offices use 4000K, neutral white, at the desks, and 3000K, warm white, at reception, in the kitchenette and in waiting areas. One room is best kept to one colour for all its fixtures. In a meeting room that also hosts guests, a fixture that changes colour helps, such as Occhio’s Mito sospeso, which moves between 2700K and 4000K.

How do you light a meeting room for video calls?

A dimmable pendant lamp over the table, and soft light on the walls. A camera that sees a window or a bright, lit wall behind the people darkens their faces, so it is better to light the wall facing them, letting the light it reflects fall on their faces, and to keep the light behind them lower. A control system such as DALI stores scenes, for example meeting, presentation and video call, and calls up each one at the touch of a button.

Does Barami Lighting design and calculate office lighting?

Yes. Barami Lighting provides lighting design and lighting calculations for the project from the makers’ photometric files (IES/LDT), passes BIM, DWG and 3D files on request, and supports the project on site as well. Architects and interior designers get special terms; everything is gathered on the page For architects and designers.

Can an office use designer light fixtures and still meet the standard?

Yes. The standard sets how much light reaches the desk and how much glare is allowed, not which fixture you choose. A common approach combines calm general light from the ceiling with designer fixtures, such as a pendant over the meeting table or a table lamp in the manager’s office. The lighting calculation takes all the fixtures together and checks that the figures hold in every area.

See the fixtures lit

At our showroom in Dan Design Center, HaLehi 2, Bnei Brak, you can see the fixtures lit, compare them and get a feel for materials and finishes before choosing. Book a meeting at the showroom, or call 054-5538204.

For architects and designers
Skip to content

Sent successfully

Thank you. We have received your details and will get back to you soon.

Book a meeting